2025 ITFAS-LEVEL-1–100% FREE VALID DUMPS QUESTIONS | TRUSTABLE NEW INSPECTION AND TESTING OF FIRE ALARM SYSTEMS LEVEL I EXAM EXAM SIMULATOR

2025 ITFAS-Level-1–100% Free Valid Dumps Questions | Trustable New Inspection and Testing of Fire Alarm Systems Level I Exam Exam Simulator

2025 ITFAS-Level-1–100% Free Valid Dumps Questions | Trustable New Inspection and Testing of Fire Alarm Systems Level I Exam Exam Simulator

Blog Article

Tags: ITFAS-Level-1 Valid Dumps Questions, New ITFAS-Level-1 Exam Simulator, Latest ITFAS-Level-1 Demo, ITFAS-Level-1 Dumps PDF, ITFAS-Level-1 Answers Real Questions

We believe that if you trust our ITFAS-Level-1 exam simulator and we will help you obtain ITFAS-Level-1 certification easily. After purchasing, you can receive our ITFAS-Level-1 training material and download within 10 minutes. Besides, we provide one year free updates of our ITFAS-Level-1 learning guide for you and money back guaranteed policy so that we are sure that it will give you free-shopping experience. Now choose our ITFAS-Level-1 practic braindump, you will not regret.

Many people dream about occupying a prominent position in the society and being successful in their career and social circle. Thus owning a valuable certificate is of paramount importance to them and passing the test ITFAS-Level-1 certification can help them realize their goals. If you are one of them buying our ITFAS-Level-1 Exam Prep will help you pass the exam successfully and easily. Our ITFAS-Level-1guide torrent provides free download and tryout before the purchase and our purchase procedures are safe.

>> ITFAS-Level-1 Valid Dumps Questions <<

New ITFAS-Level-1 Exam Simulator & Latest ITFAS-Level-1 Demo

Our ITFAS-Level-1 learning materials were developed based on this market demand. More and more people are aware of the importance of obtaining a certificate. There are more and more users of ITFAS-Level-1 practice guide. Our products can do so well, the most important thing is that the quality of ITFAS-Level-1exam questions is very good, and can be continuously improved according to market demand. And you can look at the data on our website, the hot hit of our ITFAS-Level-1 training guide can prove how popular it is!

NICET Inspection and Testing of Fire Alarm Systems Level I Exam Sample Questions (Q54-Q59):

NEW QUESTION # 54
When is a shunt trip operated to power down an elevator?

  • A. When a heat detector is tripped
  • B. When a smoke detector is tripped
  • C. When a sprinkler head is activated
  • D. When a pull station is activated

Answer: C

Explanation:
Elevators must beshut downwhen there iswater dischargein the hoistway to prevent electrical hazards and damage. This shutdown is done using ashunt trip breaker.
NFPA 72 (2022), Section 21.4.2:
"Where sprinklers are located in the elevator machine room, control space, or hoistway, means shall be provided to automatically disconnect the main power supply to the elevator prior to the application of water." This is triggeredby a waterflow switch or heat detector, but the standard design uses thesprinkler head activationas the point of shutdown via heat detector.
Important: While the heat detector usually triggers the shunt trip, thesprinkler head activationis the condition being detected.
Correct answer: D. When a sprinkler head is activated


NEW QUESTION # 55
With all notification appliances operating, what is the maximum sound pressure level, combined with the ambient sound pressure level, at the minimum hearing distance allowed by code?

  • A. 110 dBA
  • B. 105 dBA
  • C. 100 dBA
  • D. 115 dBA

Answer: B

Explanation:
NFPA 72 places amaximum allowable sound pressure levelto prevent hearing damage or discomfort in occupied areas.
NFPA 72 (2022), Section 18.4.1.5:
"The total sound pressure level produced by the fire alarm system, including ambient noise, shall not exceed
105 dBA at the minimum hearing distance from the audible appliance."
This ensures alarm audibilitywithout causing harm.
Correct answer: B. 105 dBA


NEW QUESTION # 56
Prior to any testing, all persons and facilities receiving signals and all occupants need to be notified of the testing to prevent which of the following issues?

  • A. Critical system shutdown
  • B. Unnecessary response
  • C. Elevator usage
  • D. Facility evacuation

Answer: B

Explanation:
Before performing any inspection or testing activities, it's critical tonotify all affected parties, including occupants, central stations, and local authorities (as applicable), toprevent accidental dispatch of emergency services. The reason for this is clearly stated inNFPA 72 (2022 Edition), Section 14.2.3.1, which requires notification of all stakeholders before any test.
NFPA 72:2022 - 14.2.3.1
"Prior to any testing,all persons and facilities receiving alarm, supervisory, or trouble signals, and all building occupantsshall benotifiedto preventunnecessary response." This is critical for avoiding disruptions like fire department rollouts or building evacuations that could be triggered by system activations during a test. That makes the correct answer:
D: Unnecessary response


NEW QUESTION # 57
Load testing of the control unit's VRLA batteries reveals that they must be replaced. Which two of the following are requirements for the replacement of VRLA batteries? (Choose two.)

  • A. Batteries shall be listed by a nationally recognized testing laboratory.
  • B. Batteries shall be approved by the authority having jurisdiction.
  • C. Batteries shall be marked with the month and year of manufacture.
  • D. Batteries shall be the same make and model as those being replaced.

Answer: A,C

Explanation:
Replacement batteries used in fire alarm systems must meet strict safety and documentation requirements:
NFPA 72 (2022), Section 10.6.10.1.2:
"Batteries shall be marked with the month and year of manufacture."
NFPA 72 (2022), Section 10.6.10.2:
"Batteries shall be listed for the intended purpose by a nationally recognized testing laboratory (NRTL)." There isno requirementthat replacement batteries must be the same make/model, though compatibility must be ensured.
Correct answers:
* Batteries shall be listed by a nationally recognized testing laboratory
* Batteries shall be marked with the month and year of manufacture


NEW QUESTION # 58
What is the inspection frequency of supervising station alarm system transmitters?

  • A. Semiannually
  • B. Annually
  • C. Quarterly
  • D. Monthly

Answer: C

Explanation:
Transmitters connected tosupervising stations(such as DACTs or IP communicators) must be inspected quarterlyto ensure signal integrity and physical condition.
NFPA 72 (2022), Table 14.3.1 - Inspection Frequencies:
"Supervising station transmitting equipment"#Quarterly
This includes checking for damage, loose connections, or communication issues.
Correct answer: B. Quarterly


NEW QUESTION # 59
......

If you are already determined to obtain an international certificate, you must immediately purchase our ITFAS-Level-1 exam practice. Our products have been certified as the highest quality products in the industry. If you know ITFAS-Level-1 Training Materials through acquaintance introduction, then you must also know the advantages of ITFAS-Level-1. We are both perfect on the quality and the price of the ITFAS-Level-1 study braindumps.

New ITFAS-Level-1 Exam Simulator: https://www.fast2test.com/ITFAS-Level-1-premium-file.html

We offer such service that the candidates can use free demos of New ITFAS-Level-1 Exam Simulator - Inspection and Testing of Fire Alarm Systems Level I Exam dumps torrent to their content, NICET ITFAS-Level-1 Valid Dumps Questions Our thoughtful service is also part of your choice of buying our learning materials, Once you have paid for our ITFAS-Level-1 pass4sure vce, you will receive the study guide in less than one minute, There is no doubt that the ITFAS-Level-1 prep guide has the high quality beyond your imagination.

The course includes some downloadable material that enhances the video lessons ITFAS-Level-1 and provides exercises to sharpen your requirements skills, Many years ago, we worried about video rental information getting into the wrong hands.

Web-Based NICET ITFAS-Level-1 Practice Exam Software

We offer such service that the candidates can use free demos of Latest ITFAS-Level-1 Demo Inspection and Testing of Fire Alarm Systems Level I Exam dumps torrent to their content, Our thoughtful service is also part of your choice of buying our learning materials.

Once you have paid for our ITFAS-Level-1 Pass4sure vce, you will receive the study guide in less than one minute, There is no doubt that the ITFAS-Level-1 prep guide has the high quality beyond your imagination.

NICET ITFAS-Level-1 dumps pdf can be used at any time or place.

Report this page